If the Host Address Does Not Match

Details Telesis Computer Setup Information Points of Attention
Expand All
Dept Description Sta Brass Tag Pattern Loaded Merlin Host IP PC Nic Subnet Mask
5900 Main Line 65 AAA373612 PAT08.TTP 10.177.222.225 10.177.22.232 255.255.248.0
5910 RS3 Carrier 20 AA369833 PAT07.TTP 10.177.236.223 10.177.236.228 255.255.254.0
5910 RS4 Carrier 20 AA369833 PAT07.TTP 10.177.236.223 10.177.236.229 255.255.254.0
5910 RS1 / RS2 Carrier 20 AA369822 PAT08.TTP 10.177.234.233 10.177.234.228 255.255.254.0
5920 Output Gear Assembly 10 AA372582 PAT08.TTP 10.177.231.229 10.177.231.236 255.255.254.0
5930 Gear Train 10 AAA372582 PAT08.TTP 10.177.227.140 10.177.227.147 255.255.254.0
5940 Valve Body Assembly 30 AA367947 PAT07.TTP 10.177.229.140 10.177.229.147 255.255.254.0
5950 Bell Housing 32 AAA372692 PAT08.TTP 10.177.233.103 10.177.233.108 255.255.254
  • Combination Wrench Set
  • Adjustable Crescent Wrench
  • Air Hose with Nozzle Attachment
  • Cleaning Solution (lye based)
  • Container for Cleaning Solution
  • Absorbent Towels

Make sure you are wearing proper PPE before beginning this maintenance activity. Refer to plant and department specific PPE requirements.

Lockout all stored energy sources in the work area using proper procedure. Review lockout placard and follow plant lockout procedures.

If you are unclear how to preform this task, ask your supervisor.

While performing this PM, if you discover any problems that are outside the scope of the work covered by this PM, generate a work ticket to initiate the necessary repairs AND report to your supervisor.

If this PM is not accurate please document any changes or additions that should be made and give them to your supervisor.

1: From the Merlin Software Launch Page, open the Setup window.

2: From the Steup drop-down menu, select Level, and Supervisor.

3: The Merlin Main Launch Page will not change to the Merlin Supervisor Screen.

4: From the Setup drop down menu, select Host.

5: From the Host Window, open the general tab and compare the settings.

6: Open the Socket Tab and set the Host Value. Click the OK Button to close the Setup Window.

7: Return the Steup Level to Operator.